Nut

Installation

apt-get install nut

Changes to /etc/nut configuration files

nut.conf

MODE=standalone

ups.conf

Serial

This is used on phoebus:

[phoebus]
      driver = apcsmart
      port = /dev/ttyS0

In this case, we also need /etc/udev/rules.d/99_nut-serialups.rules:

KERNEL=="ttyS0", GROUP="nut"

USB

This is used on charts, mnemosyne:

[localhost]
      driver = usbhid-ups
      port = auto
      vendorid = 051d
      

SNMP

This is used on char:

[apcups1]
      driver = snmp-ups
      port = apcups1
      mibs = apcc
      community = public

upsd.conf

This is used on UPS servers mnemosyne, charts, phoebus:

LISTEN 0.0.0.0

This is used on UPS clients, but isn't required:

LISTEN 127.0.0.1

upsd.users

This is used on char, charts:

[upsmon]
      password  = upsmon
      upsmon master
      actions = ALL
      instcmds = ALL

upsmon.conf

This is used on charts:

MONITOR localhost@localhost 1 upsmon upsmon master MINSUPPLIES 1 SHUTDOWNCMD “/sbin/halt” NOTIFYCMD /usr/bin/logger POLLFREQ 5 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME 15 POWERDOWNFLAG /etc/killpower NOTIFYMSG ONLINE “UPS %s on line power” NOTIFYMSG ONBATT “UPS %s on battery” NOTIFYMSG LOWBATT “UPS %s battery is low” NOTIFYMSG FSD “UPS %s: forced shutdown in progress” NOTIFYMSG COMMOK “Communications with UPS %s established” NOTIFYMSG COMMBAD “Communications with UPS %s lost” NOTIFYMSG SHUTDOWN “Auto logout and shutdown proceeding” NOTIFYMSG REPLBATT “UPS %s battery needs to be replaced” NOTIFYMSG NOCOMM “UPS %s is unavailable” NOTIFYMSG NOPARENT “upsmon parent process died - shutdown impossible” NOTIFYFLAG ONLINE EXEC NOTIFYFLAG ONBATT EXEC NOTIFYFLAG LOWBATT EXEC NOTIFYFLAG FSD EXEC NOTIFYFLAG COMMOK EXEC NOTIFYFLAG COMMBAD EXEC NOTIFYFLAG SHUTDOWN EXEC NOTIFYFLAG REPLBATT EXEC NOTIFYFLAG NOCOMM EXEC NOTIFYFLAG NOPARENT EXEC RBWARNTIME 43200 NOCOMMWARNTIME 300 FINALDELAY 5